SMS: Long Path Causes "Access Violation" in Invwin32.exe
ID: Q243159
|
The information in this article applies to:
-
Microsoft Systems Management Server version 1.2
SYMPTOMS
When Invwin32.exe attempts to scan a long path (longer than 256 characters), it may generate an "Access violation" error message.
RESOLUTION
A supported fix that corrects this problem is now available from Microsoft, but
it has not been fully regression tested and should be applied only to systems
experiencing this specific problem. If you are not severely affected by this
specific problem, Microsoft recommends that you wait for the next Systems Management Server service pack
that contains this fix.
To resolve this problem immediately, contact Microsoft Product Support Services
to obtain the fix. For a complete list of Microsoft Product Support Services
phone numbers and information on support costs, please go to the following
address on the World Wide Web:
http://www.microsoft.com/support/supportnet/overview/overview.asp
The English-language version of this fix should have the following file attributes or later:
Date Time Version Size File name Platform
------------------------------------------------------------
9/15/99 6:32pm 282,592 Inv32cli.exe x86
9/15/99 6:33pm 295,344 Invwin32.exe x86
9/15/99 6:34pm 865,552 Inv32cli.exe Alpha
9/15/99 6:35pm 881,936 Invwin32.exe Alpha
NOTE: Due to file dependencies, the most recent hotfix or feature that contains the above files may also contain additional files.
STATUS
Microsoft has confirmed this to be a problem in Systems Management Server version 1.2.
MORE INFORMATION
To install the hotfix, follow these steps on the Systems Management Server site server:
- Replace the Inv32cli.exe file in the
SMS_root\Site.srv\Maincfg.box\Client.src\Platform.bin
folder with the hotfix version.
- Replace the Invwin32.exe file in the
SMS_root\Site.srv\Maincfg.box\Client.src\Platform.bin
folder with the hotfix version.
- Replace the Invwin32.exe file in the
SMS_root\Site.srv\Platform.bin folder with the hotfix version.
- Maintenance Manager replicates the updated files to the Systems
Management Server logon servers on its next work cycle. To update the
clients, either manually run Upgrade.bat on each client or follow the
instructions in the following article in the Microsoft Knowledge Base:
Q166771 SMS: How to Force Site-Wide Client Updates
- A site reset is required for Invwin32.exe (SMS_INVENTORY_AGENT_NT) to be
copied to all servers managed by Site Configuration Manager. You can manually perform this process by stopping the SMS_INVENTORY_AGENT_NT service on each server and replacing the Invwin32.exe file in the SMS_root\Helper.srv\Platform.bin folder with the hotfix version.
Additional query words:
prodsms invwin32 av path gpf
Keywords : kbSMS120 kbSMS120bug kbInventory
Version : winnt:1.2
Platform : winnt
Issue type : kbbug