Operator Information Area Indicators for 3270
ID: Q107121
|
The information in this article applies to:
-
Microsoft SNA Server, versions 2.0, 2.1, 2.11, 2.11 SP1, 3.0, 4.0
The Operator Information Area (OIA)is used to display the status of a 3270
screen session. The OIA is the last (bottom) line displayed in the terminal
window of the 3270 session. Except for the initial three positions (system
connection indicators), status line indicators only appear when they apply.
The following tables describe the OIA and explain each indicator. In the
table, position refers to the column(s) that a specific indicator occupies
on the OIA, where the left-most column of the OIA is position 1. In
addition, the "female" symbol used for certain system connection and input
inhibited indicators cannot be displayed in this table. In its place is the
"^" symbol.
OIA INDICATOR (POSITION)
Symbol Meaning
--------------------------------------------------------------------------
System Connection (position 1):
Does not apply to the 3270 Applet.
System Connection (position 2):
B Connection uses an SNA protocol.
A Connection uses a non-SNA protocol.
System Connection (position 3):
b Connected to a host application (LU-LU session).
^ Connected to host system services (SSCP-LU session).
? Session is established, but is not connected to any host program
(unknown).
Session ID (positions 4 - 7):
aaaa First four characters of your configured long name session ID.
Input Inhibited messages (keyboard locked) (positions 9 - 17):
X COMMnnn Communications error. See Communications Status
(positions 19 - 26).
X MACHnnn Computer check error.
X PROGnnn Program check error. See Communications Status
(positions 19 – 26).
X SYSTEM Keyboard input is being processed by the host. Wait for the
message to clear or press RESET.
X[] The host requires more time to process your request. Wait for
the indicator to clear or press RESET.
X -f Function is not supported. Press RESET, and select a valid
function.
X^> More data was typed than the field allows or can accept.
Press RESET, and re-enter the data.
X <-^-> Protected field; you cannot type data. Press RESET, and move
the cursor to an unprotected field.
X -f^X Function is not authorized. Press RESET, and select a valid
function.
X^+? Invalid accent/character combination typed. The accent is
displayed in position 12. Press RESET, and type a valid
combination.
Communications Status (positions 19 - 26):
COMM500 All the link services configured for use by the connection
were inactive.
COMM504 Communications are not established with the host. This
message disappears as soon as communication is established with
the host. If this message does not disappear, check to ensure
proper settings of the host network address, local node ID, or
local SAP.
COMM505 The host terminated the connection used by your 3270 session.
COMM510 The host has deactivated the communications link. Report the
message to your system administrator.
COMM518 A segment was out of sequence. Contact your system
administrator.
COMM695 A communications error occurred.
COMM5nn The communications link is still being established; the keyboard
is locked. Wait for the message to clear; also check Input
Inhibited messages.
PROG703 A session control, data flow control, or network control command
is not supported. Press RESET, and try the operation again.
PROG705 A sequence number error has occurred. Press RESET, and try the
operation again.
PROG706 A chaining error has occurred. Press RESET, and try the
operation again.
PROG707 A bracket state error has occurred. Press RESET, and try the
operation again.
PROG708 A data traffic reset state exists. Press RESET, and try the
operation again.
PROG717 The support level requested is not valid. Press RESET, and
try the operation again.
PROG723 The LU type requested is not valid. Press RESET, and try the
operation again.
PROG724 The screen size requested is not valid. Press RESET, and try
the operation again.
Screen Session LU Address (positions 79 - 80):
nn The LU address of the currently displayed 3270 screen session.
ERROR 83:
The LU selected is not valid for the logged on user. There is a
configuration problem if this appears, because the emulator only
presents the user with LUs they are allowed to use. Verify the user can
use this LU.
ERROR 85:
The primary reason for this error is the specific LU requested is
already in use.
ERROR 87:
There are several possibilities for this error:
- All the LUs in the Pool requested are in use and will not be
available until someone logs off.
- One or more servers or connections are inactive, and need to be
started before all the LUs in the Pool are available.
REFERENCES
Microsoft SNA Server "3270/5250 Applet User's Guide," Appendix
Additional query words:
prodsna
Keywords : kbtool ntutil sna211 sna211sp1 sna3 sna4 sna2 sna21
Version : WINDOWS:2.0,2.1,2.11,2.11 SP1,3.0,4.0
Platform : WINDOWS
Issue type :
|