The information in this article applies to:
SYMPTOMSIf you are using a third party 5250 print emulation product over SNA Server and the print emulator is stopped, or the client-server LAN session is lost, the AS/400 printer LU session is not cleaned up properly. As a result, 5250 print emulation product cannot reconnect to the AS/400 printing device. CAUSEWhen the 5250 print emulator is stopped, a Deallocate(ABEND) negative response is generated. If the LU6.2 session is in a receive state, the response cannot be sent (according to LU6.2 protocol). RESOLUTION
This problem was corrected in SNA Server 2.11.
There is no update available for SNA Server 2.0. MORE INFORMATIONIf the application ends or the SNA Server client-server LAN session is lost, SNA Server (with the SNA Server 2.1 SNA Server service update installed) treats this condition as though the transaction program (TP) issued a TP_ENDED(HARD). The session unbinds immediately instead of trying to deallocate the conversation. Additional query words: prodsna 2.00 2.10 5250 printer unbound
Keywords : ntdistrib ntnetserv |