The information in this article applies to:
SYMPTOMS
When running an LUA/RUI application on Windows 95 using the Windows 95 SNA
Client, the application may hang.
The application never processes the return(0) statement to exit the program
until you either kill the application thru the Windows 95 task list or stop
the link service in SNA Server Admin. The printf statement executes. This
only occurs when running Named Pipes for the client interface. If you are
using TCP/IP or SPX sockets the program exits correctly. This error does
not occur on Microsoft Windows NT.
CAUSERUI_kill_session is passing an invalid locality to sbpddrop(). RESOLUTIONMicrosoft has confirmed this to be a problem in Microsoft SNA Server version 2.11. A fix to this problem is in development, but has not been regression-tested and may be destabilizing in production environments. Microsoft does not recommend implementing this fix at this time. Contact Microsoft Product Support Services for more information on the availability of this fix. Additional query words: prodsna 2.00 2.10 2.11 3.50 3.51
Keywords : |
Last Reviewed: November 18, 1999 © 2000 Microsoft Corporation. All rights reserved. Terms of Use. |