The information in this article applies to:
SYMPTOMSIf the SNA Server connection (supporting the APPC LU's being requested) does not start for any reason, the SNA Server returns an invalid sense code in the SENSE_DATA field. However, if the remote system receives an actual SNA sense code during the LU6.2 session activation, SNA Server returns the correct sense code in the [MC_]ALLOCATE response. CAUSEIf a connection fails, the SNA Server service returns the value of an uninitialized variable to the APPC interface, instead of a valid sense code. RESOLUTIONTo correct this problem, apply the fix mentioned below. STATUSMicrosoft has confirmed this to be a problem in SNA Server versions 2.0, 2.1, 2.11, and 2.11 Service Pack 1. This problem was corrected in the latest Microsoft SNA Server 2.11 U.S. Service Pack. For information on obtaining the service pack, query on the following word in the Microsoft Knowledge Base (without the spaces): S E R V P A C K Additional query words: prodsna SP1
Keywords : kbnetwork ntnetserv kbbug2.00 kbbug2.10 kbbug2.11 kbbug2.11.sp1 |
Last Reviewed: November 19, 1999 © 2000 Microsoft Corporation. All rights reserved. Terms of Use. |