The information in this article applies to:
SYMPTOMS
File transfers that use the IBM PC Support Program's RTOPC utility to
transfer data from an AS/400 to a IBM-compatible computer may fail when you
use the MS-DOS SNA Server client's ROUTER.EXE.
CAUSEThe SNA Server MS-DOS Router was not properly handling an APPC verb timeout condition if the APPC verb did not complete in 65 seconds. Instead of returning a timeout error, the MS-DOS Router was returning AP_OK (no error). RESOLUTIONThe ROUTER.EXE has been updated to correct the problem. STATUSMicrosoft has confirmed this to be a problem in SNA Server version 2.0, 2.10, 2.11, and 2.11.sp1. This problem was corrected in the latest Microsoft SNA Server 2.11 U.S. Service Pack. For information on obtaining the service pack, query on the following word in the Microsoft Knowledge Base (without the spaces): S E R V P A C K Additional query words: ca/400 service pack 1
Keywords : kbnetwork kbbug2.00 kbbug2.10 kbbug2.11 kbbug2.11.sp1 snados |
Last Reviewed: November 19, 1999 © 2000 Microsoft Corporation. All rights reserved. Terms of Use. |