UNBIND RSP Is Not Passed from SNA Server to a Downstream PU

ID: Q149801


The information in this article applies to:
  • Microsoft SNA Server, versions 2.0, 2.1, 2.11, 2.11 SP1
    on the following platforms: NT


SYMPTOMS

A device set up as a Downstream PU from an SNA Server may hang when you try to disconnect a session. Tracing on the Downstream PU will show the PU waiting on an UNBIND response from the host system.


CAUSE

SNA Server is not passing the UNBIND response from the host to the downstream PU.


RESOLUTION

A hotfix is available from Microsoft Product Support Services. Files that have been modified to correct this problem are Snaservr.exe and Trcservr.exe.


STATUS

Microsoft has confirmed this to be a problem in Microsoft SNA Server versions 2.0, 2.1, 2.11, and 2.11.sp1. This problem was corrected in the latest Microsoft SNA Server 2.11 U.S. Service Pack. For information on obtaining the service pack, query on the following word in the Microsoft Knowledge Base (without the spaces):

S E R V P A C K

Additional query words: sna nt

Keywords : kbnetwork prodsna kbbug2.00 kbbug2.10 kbbug2.11 kbbug2.11.sp1
Version : WINDOWS:2.0,2.1,2.11,2.11 SP1
Platform : WINDOWS
Issue type :


Last Reviewed: November 19, 1999
© 2000 Microsoft Corporation. All rights reserved. Terms of Use.