The information in this article applies to:
SYMPTOMSAPPC applications using the Microsoft SNA OS/2 client that make a call to a default local LU or remote LU may fail. CAUSE
The TP_STARTED verb is passing a local LU alias of all zeroes. Therefore
the APPC library goes into default LU processing, which is to query the
user record from the SNA server. For OS/2, this is done by calling the
sepdcrec()function. The wrong information is being returned on this call,
which is causing the APPC library to believe that the LU alias for this
user is a one byte value of 0x01. When the APPC library tries to use this
as the local LU alias, the SNA Server rejects it.
STATUSMicrosoft has confirmed this to be a problem in Microsoft SNA Server versions 2.1 and 2.11. This problem was corrected in the latest Microsoft SNA Server 2.11 U.S. Service Pack. For information on obtaining the service pack, query on the following word in the Microsoft Knowledge Base (without the spaces): S E R V P A C K Additional query words: OS/2 APPC TPs
Keywords : kbenv snaappc snacpic kbbug2.10 kbbug2.11 kbfix2.11.sp2 snaos2 |
Last Reviewed: November 20, 1999 © 2000 Microsoft Corporation. All rights reserved. Terms of Use. |