The information in this article applies to:
SYMPTOMSIf you use the SNA Server MS-DOS Client using Novell's ODI IPX/SPX protocol stack and the SNA Server DOS router to communicate with an AS/400, then SNA Server will log the following event prior to creating an SNA Server Dump file and Dr. Watson log: When you view the Dr. Watson log, there are faults logged against two services.
CAUSEThe trap in SNASERVR.EXE occurs when the SNA Server buffer pool becomes corrupted. In this case, the corruption occurs because the client is sending a 10-byte frame to the SNA Server when it was expecting a 47-byte frame. Because the incoming frame was smaller than expected, SNA Server fills it in with zeroes or EBCDIC spaces that cause the buffer pool to become corrupted. The trap in SNABASE.EXE results because of the preceding trap in SNASERVR.EXE. RESOLUTIONThe IPX/SPX transport now verifies that the incoming message length is valid. If the length is invalid, the message is ignored and an event 631 is logged. Microsoft has updated the <snaroot>\snanw.dll file on both the SNA Server and the client to correct this problem. STATUSMicrosoft has confirmed this to be a problem in Microsoft SNA Server version 2.11.sp1. This problem was corrected in the latest Microsoft SNA Server 2.11 U.S. Service Pack. For information on obtaining the service pack, query on the following word in the Microsoft Knowledge Base (without the spaces): S E R V P A C K Additional query words: sp1 prodsna
Keywords : kbnetwork kbbug2.11.sp1 kbfix2.11.sp2 snados |
Last Reviewed: November 20, 1999 © 2000 Microsoft Corporation. All rights reserved. Terms of Use. |