Cannot Issue Second Allocate from a CPI-C Application

ID: Q157442


The information in this article applies to:
  • Microsoft SNA Server, version 2.11 SP1
    on the following platforms: NT


SYMPTOMS

CPIC reports CM_PRODUCT_SPECIFIC_ERROR (20) when you try to issue an MC_ALLOCATE after you issue a RECEIVE_ALLOCATE and receive a TP_ID. An APPC trace will reveal a primary and secondary error codes indicating that the TP_ID is incorrect. The following event will be registered in the Application Log:

Event 3028: Error returned from APPC that does not map to CPI-C error,
00000100


CAUSE

The CPIC library was not handling APPC TP_IDs correctly if an application issues a Receive, cmrcv(), and then issues an Allocate, cmallc().


STATUS

Microsoft has confirmed this to be a problem in Microsoft SNA Server version 2.11 Service Pack 1.
This problem was corrected in the latest Microsoft SNA Server 2.11 U.S. Service Pack. For information on obtaining the service pack, query on the following word in the Microsoft Knowledge Base (without the spaces):

S E R V P A C K

Additional query words: api sp1 prodsna

Keywords : kbnetwork snacpic kbbug2.11.sp1 kbfix2.11.sp2
Version : WINDOWS:2.11 SP1
Platform : WINDOWS
Issue type :


Last Reviewed: November 20, 1999