SYMPTOMS
Terminating a 3270 session abruptly may result in a situation where a new
VTAM or host signon screen is not sent to the 3270 session. This problem
was observed in one case where a 3270 session was ended by pressing the
SYSREQ key.
This problem does not occur in SNA Server 3.0.
CAUSE
Normally, a Host is not entitled to send a BIND request for a new session
until it receives an UNBIND response. However, when a host sends an UNBIND
Type '0x0F' (UNBIND Cleanup) or any UNBIND type in the range of '0x07' to
'0x7F,' it is allowed to reset its half-session immediately. If the UNBIND
is one of these types, the host can send a BIND request before it receives
the UNBIND response.
RESOLUTION
There are no current workarounds for SNA Server versions 2.0, 2.1, 2.11, or
2.11 SP1. A 2.11 SP1 hotfix is under investigation.
STATUS
Microsoft has confirmed this to be a problem in SNA Server versions 2.0,
2.1, 2.11, and 2.11 SP1. S E R V P A C K MORE INFORMATIONThe Sense Data section of the IBM SNA Formats Guide (GA27-3136) describes Sense Code 0815xxxx as: Function Active: A request to activate a network element or procedure Additional query words: sscp msg10 prodsna