SYMPTOMSThe Windows NT Event Viewer Application log of a Windows NT Server running the TN3270 service may show repeated Event ID 903s. The event description is as follows: The TNServer traces will show a TN session initiated, but the response, DO TERM TYPE, finds nothing to receive the message. CAUSEThis can be caused by Compaq Insight Manager's use of the standard TCP/IP (Telnet) port 23. RESOLUTION
The TN3270 service can be configured to use a different port by editing the
<ntroot>\SYSTEM32\DRIVERS\ETC\SERVICES. For example, to configure the
TN3270 service to use Port 24, add the following line and restart the
TN3270 service: