The information in this article applies to:
SYMPTOMSTN3270 clients cannot proceed past the USSTAB screen (also known as a msg- 10 screen) by pressing the ENTER key. In this configuration, the clients receive the USSTAB screen from the host when the notify is sent. At the site where this problem was raised, the USSTAB screen prompted the user to press ENTER to continue. It actually accepts any keystroke, but has been written to prompt for ENTER. CAUSEThe TN3270 server receives the ENTER keystroke from the client (AID key x'7D'), but sends the host a frame with no data (a frame with a TH, RH, but no RU).
RESOLUTIONTo resolve this problem, obtain the hotfix mentioned below. STATUSMicrosoft has confirmed this to be a problem in SNA Server versions 2.0, 2.1, 2.11, and 2.11. This problem was corrected in the latest Microsoft SNA Server 2.11 U.S. Service Pack. For information on obtaining the service pack, query on the following word in the Microsoft Knowledge Base (without the spaces): S E R V P A C K Additional query words: SP1 prodsna message-10
Keywords : kbnetwork snatn3270 kbbug2.00 kbbug2.10 kbbug2.11 kbbug2.11.sp1 |