The information in this article applies to:
SYMPTOMSIn some cases, the mainframe may send the logon screen down before the RUI_WRITE on the Open has completed. If this occurs, the RUI_WRITE for the response to the logon screen fails. CAUSEA timing issue has been identified that allows the host to send the logon screen to the client prematurely. RESOLUTIONTo resolve this problem, obtain the hotfix mentioned below. In the hotfix, Winsli32.dll has been modified so that it does not issue RUI_READ for the SSCP normal flow until RUI_WRITE has completed. STATUSMicrosoft has confirmed this to be a problem in Microsoft SNA Server versions 2.0, 2.1, 2.11, 2.11 Service Pack 1, and 3.0. This problem was corrected in the latest Microsoft SNA Server 2.11 and 3.0 U.S. Service Packs. For information on obtaining the service pack, query on the following word in the Microsoft Knowledge Base (without the spaces): S E R V P A C K Additional query words: prodsna sp1 kbbug2.00 kbbug2.10
Keywords : kbnetwork snalua kbbug2.00 kbbug3.00 kbbug2.10 kbbug2.11 kbbug2.11.sp1 kbfix2.11.sp2 kbfix3.00.sp1 |
Last Reviewed: November 20, 1999 © 2000 Microsoft Corporation. All rights reserved. Terms of Use. |