The information in this article applies to:
SYMPTOMSAfter logging off of some host applications (such as TSO), a TN3270 display or printer emulator may be unable to reconnect through the TN3270 server until the user disconnects and reconnects his or her TN session. CAUSEWith some host applications (such as TSO), the host sends Deactivate Logical Unit (DACTLU) and Activate Logical Unit (ACTLU) request units to recycle the logical unit (LU) following a user logoff. The TN3270 Server component disconnects the LU after receiving the DACTLU. WORKAROUND
To work around this problem, reconnect the client.
STATUS
Microsoft has confirmed this to be a problem in Microsoft SNA Server
versions 2.11 (and all Service Packs), 3.0, and 3.0 Service Pack 1.
S E R V P A C KA supported fix for SNA Server version 2.11 is now available, but has not been fully regression-tested and should be applied only to s ystems experiencing this specific problem. Unless you are severely impacted by this specific problem, Microsoft recommends that you wait for the next Service Pack that contains this fix. Contact Microsoft Product SupportServices for more information. Additional query words: sp1 prodsna
Keywords : kbnetwork snalua snatn3270 kbbug2.11 kbbug2.11.sp1 kbfix2.11.sp2 kbfix3.00.sp2 |
Last Reviewed: September 23, 1999 © 2000 Microsoft Corporation. All rights reserved. Terms of Use. |