The information in this article applies to:
SYMPTOMS
Microsoft SNA Server versions 2.11 and later provide support for
Dynamically Defined Dependent LUs (DDDLU) for 3270 LUs. However, DDDLU
support for LUA LUs is not provided in SNA Server.
Q161492 LU Session Activation Using Dynamically Defined Dependent LUs CAUSEWhen DDDLU support was originally added to SNA Server, DDDLU support was only implemented for 3270 LUs. RESOLUTIONAn update to SNA Server 3.0 is available. It provides DDDLU support for LUA LUs. By default, DDDLU support for LUA LUs is disabled. To enable this support, the following registry entry must be set to specify the Model Number to be requested by SNA Server when an LUA LU is dynamically activated.
Model Number can be 1 through 5 to correspond to supported
3270 Model Numbers.
The following files were updated to add this support: <snaroot>\system\snaservr.exe STATUSMicrosoft has confirmed this to be a problem in SNA Server versions 2.11, 2.11 SP1, and 3.0. This problem was corrected in the latest Microsoft SNA Server 3.0 U.S. Service Pack. For information on obtaining the service pack, query on the following word in the Microsoft Knowledge Base (without the spaces): S E R V P A C K Additional query words: lugroup luseed
Keywords : prodsna snalua kbbug3.00 kbbug2.11 kbbug2.11.sp1 kbfix3.00.sp1 snaserverservice |
Last Reviewed: November 23, 1999 © 2000 Microsoft Corporation. All rights reserved. Terms of Use. |