Connection for Downstream PU Fails to Reactivate After Outage

ID: Q165656


The information in this article applies to:
  • Microsoft SNA Server, version 3.0


SYMPTOMS

A downstream connection fails to activate after an outage even though both stations are ready.


CAUSE

If SNA Server received a reactivation XID while it was processing the outage, it would set the link in a state from which it could not reactivate. The connection would have to be manually reset for it to reactivate.

NOTE: This article is related to the following Knowledge Base article, which documents a similar (but not identical) issue for SNA Server version 2.11:

Q150472 Downstream PU Fails to Reactivate After an Outage


RESOLUTION

The components have been instructed to not pass reactivation XIDs to the server component until it has finished processing the outage.


STATUS

Microsoft has confirmed this to be a problem in SNA Server version 3.0. This problem was corrected in the latest Microsoft SNA Server 3.0 U.S. Service Pack. For information on obtaining the service pack, query on the following word in the Microsoft Knowledge Base (without the spaces):

S E R V P A C K

Additional query words: dspu down stream

Keywords : kbnetwork prodsna kbbug3.00 kbfix3.00.sp1 snadlc
Version : WINDOWS:3.0
Platform : WINDOWS
Issue type : kbbug


Last Reviewed: November 23, 1999
© 2000 Microsoft Corporation. All rights reserved. Terms of Use.