Application Hangs if WinRUIStartup is Called Before WinAPPCStartup

ID: Q170286


The information in this article applies to:
  • Microsoft SNA Server, versions 2.11, 3.0


SYMPTOMS

If an application attempts to open the SNA Server Windows APPC and RUI interfaces from the same process, the application may hang if WinRUIStartup() is called before WinAPPCStartup().

NOTE: The RUI interface provides access to LU0-3 host applications, while APPC provides access to partner APPC transaction programs over LU6.2.


RESOLUTION

To workaround the problem, WinAPPCStartup should be called before WinRUIStartup.


STATUS

Microsoft has confirmed this to be a problem in SNA Server, versions 2.11 and 3.0. We are researching this problem and will post new information here in the Microsoft Knowledge Base as it becomes available.

Additional query words: winappc winrui winlua

Keywords : prodsna snaprog
Version : WINDOWS:2.11,3.0
Platform : WINDOWS
Issue type :


Last Reviewed: November 24, 1999