The information in this article applies to:
SYMPTOMSThe Microgate SDLC link service cannot be installed on an Alpha computer with SNA Server version 3.0 and 3.0 SP1, except as an external link service. When installing the Microgate SDLC link service as internal, the Card Configuration tab and Dialer Settings tab do not contain information. When installing the link service as external, all of the information is entered in the correct fields. WORKAROUNDInstall the link service as an external link service. STATUSMicrosoft has confirmed this to be a problem in Microsoft SNA Server, versions 3.0 and 3.0 SP1. We are researching this problem and will post new information here in the Microsoft Knowledge Base as it becomes available. Additional query words:
Keywords : prodsna sna3rdparty snadlc snamanager |
Last Reviewed: November 17, 1999 © 2000 Microsoft Corporation. All rights reserved. Terms of Use. |