SYMPTOMS
When an SNA Server 3270 EIS application calls sbpuinit() on a Windows 95
client configured to use a non-named pipe transport (for example, TCP/IP
sockets, IPX/SPX, or Banyan IP), the SNA client software displays a user
logon dialog box. If the user cancels this logon dialog box, the sbpuinit()
function returns incorrectly with error 563 (DMDSTFL, or "service table
full"), instead of error 625 (DMNONAP, or "NAP not up when starting
service").
CAUSEThe SNA Server Windows 95 Snadmod.dll does not retrieve the correct error to the sbpuinit() function when the logon dialog box is cancelled. STATUSMicrosoft has confirmed this to be a problem in the SNA Server Windows 95 client version 3.0 and 3.0 Service Pack 1 (SP1). This problem was corrected in the latest SNA Server version 3.0 U.S. Service Pack. For information on obtaining this Service Pack, query on the following word in the Microsoft Knowledge Base (without the spaces): S E R V P A C K MORE INFORMATIONThe updated Windows 95 client modules are snakrnl.dll and snadmod.dll. Additional query words:
Keywords : kbnetwork snaprog snaeis snawin95 kbfix3.00.sp2 |