TN3270 Server Incorrectly Truncates Last Character of SSCP Data

ID: Q171935


The information in this article applies to:
  • Microsoft SNA Server, versions 2.11, 2.11 SP1, 2.11 SP2, 3.0, 3.0 SP1
    on the following platforms: NT


SYMPTOMS

When you connect through the SNA Server TN3270 server using a TN3270 emulator, the last character of the initial host screen (USSMSG10) does not appear.


CAUSE

The SNA Server TN3270 server incorrectly truncates the last character of SSCP data. This problem only occurs with TN3270 sessions. If an emulator connects using TN3270E protocol, this problem does not occur.


RESOLUTION

A hotfix to SNA Server 3.0 (post SP1) is available to correct this problem. The updated module is Tn3servr.exe.


STATUS

Microsoft has confirmed this to be a problem in SNA Server 3.0 and 3.0 Service Pack 1 (SP1). This problem was corrected in the latest SNA Server version 3.0 U.S. Service Pack. For information on obtaining this Service Pack, query on the following word in the Microsoft Knowledge Base (without the spaces):

S E R V P A C K

Additional query words:

Keywords : kbnetwork prodsna snatn3270 kbbug3.00 kbbug2.11 kbbug2.11.sp1 kbbug2.11.sp2 kbbug3.00.sp1 kbfix3.00.sp2
Version : WINDOWS:2.11,2.11 SP1,2.11 SP2,3.0,3.0 SP1
Platform : WINDOWS
Issue type : kbbug


Last Reviewed: November 24, 1999
© 2000 Microsoft Corporation. All rights reserved. Terms of Use.