SYMPTOMSIBM CICS for Windows NT fails to work when connecting through SNA Server 3.0, though it had been previously working through SNA Server 2.11. CAUSE
When IBM CICS for Windows NT initializes, it calls the APPC DISPLAY
verb to determine what SNA Servers are active. It then calls DISPLAY
again requesting information on all active APPC LU's on the active
server.
RESOLUTIONIf partnerships are defined in the SNA Server 3.0 configuration file, the above error does not occur. To define a partnership using SNACFG.EXE, use the following command: SNACFG APPCLLU servername:locallu /ADDPARTNER:remotelu,mode,connectionThe SNA Server service must be stopped and restarted to implement this change. The ability to define Local/Remote/Mode partnerships is being added in the SNA Server 3.0 Service Pack 2 version of Manager. If SNA Server 3.0 or 3.0 Service Pack 1 is being used, the SNACFG.EXE command line configuration tool must be used to define an APPC LU partnership. Additional query words:
Keywords : kbprg prodsna sna3rdparty snaappc snaprog |