Snacfg.exe Does Not Support Omission of LOCALBLOCKNO

ID: Q172291


The information in this article applies to:
  • Microsoft SNA Server, versions 3.0, 3.0 SP1
    on the following platforms: NT


SYMPTOMS

When you configure an SDLC connection using Snacfg.exe, if the LOCALBLOCKNO (the first three digits of the Local Node ID, also known as the IDBLK) value is omitted, you receive the following error message:

The first three digits of the Local Node ID are invalid. These digits, also called the Block Number, can be any three hexadecimal digits except 000 or FFF, which are reserved.


CAUSE

Snacfg.exe does not set the SDLC connection "fSdlcLeased" flag based on the specified link service. If this flag is not set, the validate routine in Snacfg.exe does not recognize the connection as being associated with a Leased SDLC link service and considers the omission of the IDBLK as invalid.


RESOLUTION

Snacfg.exe has been corrected so that it now verifies the specified link service is SDLC and Leased. If the link service meets both these criteria, the IDBLK value can be omitted.


STATUS

Microsoft has confirmed this to be a problem in SNA Server 3.0 and 3.0 Service Pack 1 (SP1). This problem was corrected in the latest SNA Server version 3.0 U.S. Service Pack. For information on obtaining this Service Pack, query on the following word in the Microsoft Knowledge Base (without the spaces):

S E R V P A C K

Additional query words: snacfg snaconfig

Keywords : kbenv kbnetwork prodsna kbbug3.00 kbbug3.00.sp1 snasdlc snasetup kbfix3.00.sp2
Version : WINDOWS:3.0,3.0 SP1
Platform : WINDOWS
Issue type : kbbug


Last Reviewed: November 17, 1999