The information in this article applies to:
SYMPTOMSIf the name of a Logical Unit (LU) is the same as the name of the workstation this particular LU is assigned to, it will disappear from within SNA Manager after SNA Manager has been restarted. CAUSESNA Manager uses the same function when checking both for duplicate workstation entries and for duplicate workstation LU configuration records. SNA Manager does not distinguish between the two. So, when a workstation is found with the same name as the workstation LU record being added, it will fail because it is assumed to be a duplicate Workstation name. STATUSMicrosoft has confirmed this to be a problem in SNA Server versions 3.0 and 3.0 Service Pack 1 (SP1). This problem was corrected in the latest SNA Server version 3.0 U.S. Service Pack. For information on obtaining this Service Pack, query on the following word in the Microsoft Knowledge Base (without the spaces): S E R V P A C K Additional query words:
Keywords : kbnetwork snaadmin kbfix3.00.sp2 |
Last Reviewed: November 24, 1999 © 2000 Microsoft Corporation. All rights reserved. Terms of Use. |