SNA Server Connection to AS/400 Remains in Pending State
ID: Q172809
|
The information in this article applies to:
-
Microsoft SNA Server, versions 2.0, 2.1, 2.11, 3.0
SYMPTOMS
When you activate an SNA Server 802.2 DLC connection to an AS/400 (over
Token Ring or over Ethernet), the SNA Server connection status remains
Pending. This can occur if the AS/400 line description is in an RCYPND
(Recovery Pending) status. To check for this condition, issue the following
AS/400 command:
WRKCFGSTS *lin <line name> or WRKLIND <line name> then option 8 to work
with configuration status
NOTE: There also may be an Application event log error similar to the
following:
Event ID: 230
Description: Remote station not responding to XID commands
WORKAROUND
If the AS/400 line status is RCYPND, do the following:
- Stop the SNA Server connection from the SNA Server Admin or Manager.
- From the AS/400 WRKCFGSTS screen, choose option 2 to vary off the line
status. Wait for the line to show a status of Varied Off. (Press F5 to
refresh the screen.)
- Choose option 1 to Vary On the line description. Press F4 for the Vary
Configuration dialog box. The last option in this box is Reset, which is
No by default. Change to Yes. This will reset the Ethernet Card in the
AS/400. Status should then change on the AS/400 to Vary On Pending.
- Restart the SNA Server service. The connection should become active.
If the AS/400 line description is not in Recovery Pending status, then
check for these other possible causes:
- Determine whether the APPC controller status is Recovery Pending also.
- Check for one of the conditions described in the following Microsoft
Knowledge Base article:
Q126393 SNA Server Configurations That Produce XID Rejections
- If you are connecting to an AS/400 across a Cisco router, check the
following Knowledge Base article:
Q159462 SNA Server 802.2 Connection Stays in Pending State
Additional query words:
Keywords : prodsna sna5250 snadlc
Version : WINDOWS:2.0,2.1,2.11,3.0
Platform : WINDOWS
Issue type : kbprb
|