SNA Manager Fails to Open Backup Config File.

ID: Q173341


The information in this article applies to:
  • Microsoft SNA Server, versions 3.0, 3.0 SP1


SYMPTOMS

When you start the SNA Manager while the Windows NT Server computer that hosts the primary SNA Server computer is not reachable, the following message is displayed:

From SNAOLE - Configuration file not found.
When you click OK in response to this message, SNA Manager reports the following on the information bar of the subdomain window:
CONFIG READ FAILED rc = 3935


CAUSE

This only happens if the backup SNA Server computer where SNA Manager is running was able to read the configuration file from the Primary SNA Server when it started. The configuration path in the shared memory then points to the primary SNA Server computer because that is the currently active configuration file. There is no mechanism to switch to a backup configuration file other than at startup time.


STATUS

Microsoft has confirmed this to be a problem in SNA Server versions 3.0 and 3.0 Service Pack 1. This problem was corrected in the latest SNA Server version 3.0 U.S. Service Pack. For information on obtaining this Service Pack, query on the following word in the Microsoft Knowledge Base (without the spaces):

S E R V P A C K


MORE INFORMATION

With the fix applied, if SNA Manager fails to open the currently active configuration file, the following message is displayed:

Unable to open the Primary SNA Server configuration file. Okay to attempt opening a Backup SNA Server in read-only mode?

If you click OK, SNA Manager looks for a backup configuration file to open.

Additional query words:

Keywords : kberrmsg kbnetwork snamanager kbfix3.00.sp2
Version : WINDOWS:3.0,3.0 SP1
Platform : WINDOWS
Issue type : kbbug


Last Reviewed: December 3, 1999