The information in this article applies to:
SYMPTOMS
Users are logged on to a CICS application via the TN3270(E) server. The
CICS application frequently writes data to the user's terminal. At random
times, users are suddenly disconnected and have to log on again.
A trace will show the user's session ended with a TERM-SELF and UNBIND.
CAUSEAn unusual sequence of messages results in correlation errors being received from the SNA Server service. The TN3270(E) service treats the correlation errors as fatal errors, resulting in the sessions being disconnected. STATUS
The TN3270(E) service has been updated so that the correlation error is not
handled as a fatal error. This change allows the TN3270 session to be
maintained when this error occurs.
S E R V P A C KA supported fix for SNA Server version 2.11 is now available, but has not been fully regression-tested and should be applied only to systems experiencing this specific problem. Unless you are severely impacted by this specific problem, Microsoft recommends that you wait for the next Service Pack that contains this fix. Contact Microsoft Product Support Services for more information. Additional query words:
Keywords : snatn3270 kbfix3.00.sp3 |
Last Reviewed: November 17, 1999 © 2000 Microsoft Corporation. All rights reserved. Terms of Use. |