The information in this article applies to:
SYMPTOMSIn some situations, such as performing a screen save from a TN5250 session to the AS400, the APPC session fails (the AS/400 rejects one of the messages) and an Event ID 16 is logged from the TN5250 Service on the SNA Server computer with the following text:
CAUSEIn some cases, the data flow comes across two socket calls. The TN5250 Service is incorrectly handling the second call, causing the problem to occur. RESOLUTIONSNA Server 4.0This problem was corrected in the latest SNA Server version 4.0 U.S. Service Pack. For information on obtaining this Service Pack, query on the following word in the Microsoft Knowledge Base (without the spaces):S E R V P A C K SNA Server 3.0To resolve this problem, obtain the latest service pack for SNA Server version 3.0. For additional information, please see the following article in the Microsoft Knowledge Base:Q184307 How to Obtain the Latest SNA Server Version 3.0 Service Pack STATUSMicrosoft has confirmed this to be a problem in Microsoft SNA Server, versions 3.0, 3.0 SP1, 3.0 SP2, 3.0 SP3, 4.0. This problem was first corrected in SNA Server 3.0 Service Pack 4. MORE INFORMATIONWith the update applied, the TN5250 Service functions correctly in this situation. Additional query words:
Keywords : kbfix4.00.sp1 snaappc snatn5250 |
Last Reviewed: December 2, 1999 © 2000 Microsoft Corporation. All rights reserved. Terms of Use. |