Dynamic Definition of Dependent APPC LUs Doesn't Work Properly

ID: Q182577


The information in this article applies to:
  • Microsoft SNA Server, versions 3.0, 3.0 SP1, 3.0 SP2, 4.0


SYMPTOMS

If a dependent Local APPC LU is defined on two different connections (where each connection is configured to support Dynamic Definition of Remote APPC LUs), and the APPC application attempts to allocate a conversation over each Local LU to the same Remote APPC LU, the SNA INITSELF command for both dependent sessions flows over the first connection only.


CAUSE

Dynamic definition of dependent APPC LUs is not working correctly. If two remote APPC LUs are given the same name but defined to use different connections, the allocate to the second APPC LU causes the initself command to be sent across the wrong connection.


RESOLUTION

SNA Server 3.0

To resolve this problem, obtain the latest service pack for SNA Server version 3.0. For additional information, please see the following article in the Microsoft Knowledge Base:
Q184307 How to Obtain the Latest SNA Server Version 3.0 Service Pack

SNA Server 4.0

This problem was corrected in the latest SNA Server version 4.0 U.S. Service Pack. For information on obtaining this Service Pack, query on the following word in the Microsoft Knowledge Base (without the spaces):
S E R V P A C K


STATUS

Microsoft has confirmed this to be a problem in SNA Server 3.0, 3.0 SP1, 3.0 SP2, and 4.0. This problem was first corrected in SNA Server 3.0 Service Pack 4.

Additional query words:

Keywords : kbfix4.00.sp1 prodsna snaappc snacpic snaprog snaserverservice
Version : WINDOWS:3.0,3.0 SP1,3.0 SP2,4.0
Platform : WINDOWS
Issue type : kbbug


Last Reviewed: November 18, 1999
© 2000 Microsoft Corporation. All rights reserved. Terms of Use.