The information in this article applies to:
SYMPTOMSIf an APPC application is using confirmation processing on an LU6.2 conversation and receives an MC_RECEIVE_AND_WAIT response with a what_rcvd value of AP_CONFIRM_DEALLOCATE (0x0400), the application's call to MC_CONFIRMED may stop responding. CAUSEThe SNA Server was not resetting an error indicator on an internal LU6.2 control block between reuses of the control block. So, if an error occurs on a prior conversation over a session (for example, following an APPC application issuing an [MC_]SEND_ERROR), the current conversation may fail unexpectedly when the current session is brought down incorrectly. STATUS
Microsoft has confirmed this to be a problem in SNA Server versions 3.0,
3.0 SP1, and 3.0 SP2. Microsoft is researching this problem and will post
new information here in the Microsoft Knowledge Base as it becomes
available.
S E R V P A C K Additional query words:
Keywords : kbfix4.00.sp1 prodsna snaappc snacpic snaprog snaserverservice |
Last Reviewed: November 18, 1999 © 2000 Microsoft Corporation. All rights reserved. Terms of Use. |