The information in this article applies to:
SYMPTOMS
3270 EIS (Emulator Interface Specification)/FMI (Function Management
Interface) applications used with SNA Server fail if the application BIND
received from the host specifies an RU (Request Unit) size of 32 KB. SNA
Server will send the BIND to the 3270 application in an OPEN PLU REQUEST
message. The 3270 Applet included with SNA Server responds to this message
with an OPEN PLU CONFIRM ERROR (Err1:0821 Err2:000A). SNA Server then sends
a BIND -RSP to the host with an IBM Sense Code of 0835000A. Other 3270
applications may return slightly different errors.
CAUSESNA Server stores the maximum RU size in a signed two-byte integer which is capable of storing values up to +32767. The value of 32 KB is 32768, which is larger than can be stored in that signed two-byte integer. As a result, all FMI applications using 32 KB RUs are rejected. RESOLUTION
Microsoft has confirmed this to be a problem in SNA Server Versions 3.0,
3.0 SP1, 3.0 SP2, 3.0 SP3, 4.0, and 4.0 SP1. We are researching
this problem in SNA Server version 3.0 and will post more information
here in the Knowledge Base as it becomes available.
S E R V P A C K MORE INFORMATIONPlease refer to the IBM SNA Formats Guide (GA27-3136) for more details on how the RU size is specified in the BIND. IBM Sense Codes are also documented in this manual, which is also available on the SNA Server 4.0 CD (I386\Sdk\Formats.hlp). Additional query words:
Keywords : |
Last Reviewed: September 22, 1999 © 2000 Microsoft Corporation. All rights reserved. Terms of Use. |