The information in this article applies to:
SYMPTOMSOnly one SDLC connection to a Downstream PU (DSPU) will function correctly even though multiple SDLC connections are configured for concurrent usage to multiple DSPUs over the same SDLC adapter. Even though only one connection is actually in use at a time, SNA Server Manager shows an active status for all of the configured DSPU SDLC connections. This was reported by a customer using the IBM MPCA SDLC adapter, but can occur with any SDLC adapter that uses the SDLC "dumb card" driver interface provided by SNA Server. RESOLUTIONSNA Server 3.0To resolve this problem, obtain the latest service pack for SNA Server version 3.0. For additional information, please see the following article in the Microsoft Knowledge Base:Q184307 How to Obtain the Latest SNA Server Version 3.0 Service Pack SNA Server 4.0This problem was corrected in the latest SNA Server version 4.0 U.S. Service Pack. For information on obtaining this Service Pack, query on the following word in the Microsoft Knowledge Base (without the spaces):
STATUSMicrosoft has confirmed this to be a problem in the products listed at the beginning of this article. This problem was first corrected in SNA Server 3.0 Service Pack 4. Additional query words: MPCA DSPU
Keywords : |
Last Reviewed: July 8, 1999 © 2000 Microsoft Corporation. All rights reserved. Terms of Use. |