Unable to Correlate SLI_OPEN Request With SLI BIND Routine

ID: Q198180


The information in this article applies to:
  • Microsoft SNA Server, versions 3.0, 4.0
  • Microsoft SNA Server version 3.0 Service Packs 1, 2, and 3
  • Microsoft SNA Server version 4.0 Service Pack 1


SYMPTOMS

If an SLI application makes multiple SLI_OPEN calls to open an LUA pool, and registers a BIND routine callback procedure, the SLI application has no way to correlate the BIND routine with the original SLI_OPEN request, when the application's BIND routine procedure is called. The lua_correlator field provided to the SLI_OPEN request is not provided to the application's BIND routine.


CAUSE

The SNA Server SLI DLL file (Winsli32.dll) was failing to provide the lua_correlator field to the SLI application's BIND routine while an SLI_OPEN request is being processed.


RESOLUTION

SNA Server 4.0

To resolve this problem, obtain the latest service pack for SNA Server version 4.0. For additional information, please see the following article in the Microsoft Knowledge Base:
Q215838 How to Obtain the Latest SNA Server Version 4.0 Service Pack

SNA Server 3.0

To resolve this problem, obtain the latest service pack for SNA Server version 3.0. For additional information, please see the following article in the Microsoft Knowledge Base:
Q184307 How to Obtain the Latest SNA Server Version 3.0 Service Pack


STATUS

Microsoft has confirmed this to be a problem in SNA Server versions 3.0 and 4.0. This problem was first corrected in SNA Server version 3.0 Service Pack 4 and SNA Server version 4.0 Service Pack 3.

Additional query words:

Keywords : sna3sp4fix sna4sp3fix
Version : WINDOWS:3.0,3.0SP1,3.0SP2,3.0SP3,4.0,4.0SP1
Platform : WINDOWS
Issue type : kbbug


Last Reviewed: September 29, 1999
© 2000 Microsoft Corporation. All rights reserved. Terms of Use.