The information in this article applies to:
SYMPTOMSWhen using the SNA Print Server to support print emulation to an AS/400 or S/36, Event 4097 may be logged even when no error has actually occurred. For example: This event was logged when testing the SNA Print Server against an IBM S/36, when the S/36 print writer for the print device was not started. CAUSEThe SNA Print Service logs this error whenever one of its APPC function calls completes when AP_OK is not the primary return code. However, in some cases, an APPC primary return code of AP_DEALLOC_NORMAL (0x0009) may not indicate an actual error condition. RESOLUTIONTo resolve this problem, obtain the latest service pack for SNA Server version 4.0. For additional information, please see the following article in the
Microsoft Knowledge Base: Q215838 How to Obtain the Latest SNA Server Version 4.0 Service Pack STATUSMicrosoft has confirmed this to be a problem in SNA Server 4.0, 4.0 SP1 and 4.0 SP2. This problem was first corrected in SNA Server version 4.0 Service Pack 3. Additional query words:
Keywords : sna4sp3fix |
Last Reviewed: September 29, 1999 © 2000 Microsoft Corporation. All rights reserved. Terms of Use. |