SYMPTOMSAn SDLC connection configured to use the MicroGate T1 SDLC Adapter from MicroGate Corp. may stay in pending status. CAUSEThe incorrect interface (RS232, RS422, or V.35) may have been selected on the adapter. RESOLUTIONSet the J5, J6, or J7 jumper to the correct interface type. MORE INFORMATION
There are three jumper settings that correlate to the types of interface. The J5 jumper selects RS-232, J6 selects V.35, and J7 selects RS-422. RS-232 is generally associated with analog modems at 2400 to 19.2 baud, V.35 is a digital interface using CSU/DSUs (Channel Service Unit/Data Service Unit) at 56 kb per second or greater, and RS-422 is a differential standard using a DB-25 connector. It is most frequently used in Europe. Additional query words: