The information in this article applies to:
SYMPTOMS
If an AS/400 application screen contains an input field that requires certain values, the Win5250 applet prevents the user from exiting the screen using a function key unless a valid value is entered in the field.
CAUSEThe 5250 applet was incorrectly processing the input field(s) prior to the handling of function keys. RESOLUTIONA supported fix that corrects this problem is now available from Microsoft, but
it has not been fully regression tested and should be applied only to systems
experiencing this specific problem. If you are not severely affected by this
specific problem, Microsoft recommends that you wait for the next Microsoft SNA Server 4.0 service pack
that contains this fix. http://www.microsoft.com/support/supportnet/overview/overview.aspThe English version of this fix should have the following file attributes or later:
NOTE: Because of file dependencies, the most recent fix that contains the above files may also contain additional files. STATUSMicrosoft has confirmed this to be a problem in Microsoft SNA Server 3.0 (including SP1-SP4) and 4.0 (including SP1-SP3). Additional query words:
Keywords : kbDSupport kbsna |
Last Reviewed: November 9, 1999 © 2000 Microsoft Corporation. All rights reserved. Terms of Use. |