Winmgt32.dll May Complete Same Verb Three Times

ID: Q245966


The information in this article applies to:
  • Microsoft SNA Server, versions 4.0 SP2, 4.0 SP3


SYMPTOMS

The SNA Server Winmgt32.dll file may complete the same asynchronous ACTIVATE_SESSION or DEACTIVATE_SESSION verb three times in error.


CAUSE

This can happen if the Activate/Deactivate_SESSION verb completes before the calling thread has exited the Winmgt32.dll file.


STATUS

Microsoft has confirmed this to be a problem in Microsoft SNA Server Version 4.0 SP2, 4.0 SP3.


MORE INFORMATION

Support for ACTIVATE_SESSION and DEACTIVATE_SESSION is included in SNA Server 4.0 SP2 and later versions. For additional information, click the article number below to view the article in the Microsoft Knowledge Base:

Q195010 Activate_session/Deactivate_session Unavailable in SNA Server

Additional query words:

Keywords :
Version : WINDOWS:4.0 SP2,4.0 SP3
Platform : WINDOWS
Issue type : kbbug


Last Reviewed: November 18, 1999