SYMPTOMSIf an invalid printer type is manually entered in the Host Print Transform Printer Type User Interface, the print session stays pending, and the Application Event Log may record the following event:
CAUSEHost Print Transform (HPT) is a utility on the AS/400 that formats the data stream in an ASCII stream with embedded control characters to format the data to match the selected printer type. The printer type configured on the SNA Server computer is passed to the AS/400 in the ATTACH. RESOLUTION
Although it is possible to manually enter values, and required in SNA Server 3.0, the SNA Server 4.0 interface has a drop-down list box to select the printer type. Use the drop-down lest box instead of manual entry whenever possible.
MORE INFORMATIONThere are many other reasons that this event is posted. For additional information, click the article numbers below to view the articles in the Microsoft Knowledge Base: Q222940 SNA 5250 Print Service (PPV5250) May Log Event 4097 In Error Q224825 Event 4097 Logged Continuously By 5250 Print SessionThe third-party products discussed in this article are manufactured by vendors independent of Microsoft; we make no warranty, implied or otherwise, regarding these products' performance or reliability. Additional query words:
Keywords : |