The information in this article applies to:
SYMPTOMS
Microsoft TCPIP Sockets for Windows (using DBMSSOC3.DLL) connections are
only supported using Microsoft Windows for Workgroups version 3.11 and
Microsoft TCPIP for Windows for Workgroups. Microsoft TCPIP sockets for
Windows connections will timeout if the initial TCP Session setup takes
more than 5 seconds.
MORE INFORMATION
If you are experiencing connection problems with Winsock using
DBMSSOC3.DLL, you can now adjust the socket connect and name resolution
timeouts by adding an entry to the [SQLSERVER] section in the WIN.INI file.
This option is only available with DBMSSOC3.DLL version 4.21.05 dated
7/15/94. For example:
If the entry is not found by DBMSSOC3.DLL, then the Network Library (Net- Library) timeout defaults to 5 seconds. Additional query words: Windows NT
Keywords : kbtool SSrvNet_Lib SSrvServer SSrvWinNT |
Last Reviewed: March 20, 1999 © 2000 Microsoft Corporation. All rights reserved. Terms of Use. |