The information in this article applies to:
BUG# NT: 10665 (4.21a) SYMPTOMS
Remote Stored Procedure calls (RPC) from Sybase SQL Server versions 4.8 and
4.92 on UNIX platforms to Microsoft SQL Server via TCP/IP may fail with the
following error message:
This failure may occur when remotely executing any stored procedures, such as sp_who. CAUSE
The server-side network library for TCP/IP (SSMSOCN.DLL) incorrectly
handles the RPC requests from certain versions of Sybase SQL Server on the
UNIX platforms.
WORKAROUND
Replace the server-side network library SSMSSOCN.DLL with version 4.21
(dated 1/26/94). If you experience any out-of-band data problems (such as
invalid buffer errors on the client)after switching to the older version,
you may avoid them by adding the following entry to the NT 3.5 registry:
For additional information, please see the following article in the Microsoft Knowledge Base: Q120642 :TCP/IP & NBT Configuration Parameters for Windows NT 3.5 STATUSMicrosoft has confirmed this to be a problem in Microsoft SQL Server version 4.21a. This problem was corrected in the latest U.S. Service Pack for SQL Server version 4.21a. For information on obtaining the Service Pack, please contact your primary support provider. Additional query words: rpc tcp/ip Sybase net-library Windows NT
Keywords : |
Last Reviewed: April 20, 1999 © 2000 Microsoft Corporation. All rights reserved. Terms of Use. |