INF: SQL Server and ODS Sample Gateway on One Machine
ID: Q89365
|
The information in this article applies to:
-
Microsoft SQL Server for OS/2, version 4.2
SUMMARY
By default, SQL Server listens on the default pipe \PIPE\SQL\QUERY.
This article describes the method for using an alternate pipe to set
up SQL Server and an Open Data Services (ODS) application (sample
gateway) on a single machine. This can be achieved in two ways:
- Starting SQL Server on an alternate pipe and making the ODS
application listen to the default pipe.
- Starting SQL Server to listen on the default pipe and starting the
ODS application on an alternate pipe.
This article gives step-by-step instructions on how to set up the
first option. The second option can be set up similarly. The
DB-Library (DB-Lib) clients, by default, communicate through default
pipes. In either case, the client sides might need to be modified, by
making appropriate entries in the AUTOEXEC.BAT file (MS-DOS), the
WIN.INI file (Windows), and the OS2.INI file (OS/2) in order to
communicate through alternate pipes.
Let the machine, where both SQL Server and the sample gateway are
going to run, be called \\GEORGE. Then on this machine:
- Start SQL Server on an alternate pipe, say newpipe, by executing
the following:
sqlservr -dc:\sql\data\master.dat -pnewpipe
On a LAN Manager network, you can start SQL Server on an
alternate pipe, as a network service. This is documented in the
READ.ME file in the OPENDS directory and is done by making the
following entry in the LANMAN.INI file:
[sqlserver]
database = c:\sql\data\master.dat
errorlog = c:\sql\log\errorlog
executable = c:\sql\binp\sqlservr.exe
-pnewpipe
These commands will start SQL Server, listening on the pipe
\PIPE\NEWPIPE\QUERY.
- Start the sample gateway program in a different screen group
gateway -Snewserv
where "newserv" is a logical name and corresponds to the following
entry in the OS2.INI file on \\GEORGE:
App: SQLSERVER
Key: newserv
Value: dbnmpp,\pipe\newpipe\query
This entry can be made using the INIEDIT.EXE or WRITEINI.EXE
utilities that come with the Open Data Services. By default, when
clients connect to \\GEORGE, they will connect to the sample
gateway application, which in turn has a connection to SQL Server
on the same machine, through the pipe \PIPE\NEWPIPE\QUERY.
Additional query words:
DB_Library db-lib
Keywords : kbprg SSrvODS SSrvProg
Version : 4.2
Platform : OS/2
Issue type :
|