MS DLC Fails to Respond to TEST Frames.

ID: Q119399


The information in this article applies to:
  • Microsoft LAN Manager, version 2.2


SYMPTOMS

Applications fail if they are based on the real mode Microsoft Data Link Control (MSDLC) stack and use TEST frames to initiate a connection.


CAUSE

As the default, MSDLC does not pre-allocate SAP transmit buffers, and does not respond to TEST frames sent to any SAP except SAP 0 (Global SAP, reserved).


RESOLUTION

Make this entry to force MSDLC to pre-allocate transmit buffers on SAPs:


    PROTOCOL.INI
   [msdlc_xif]
        trxbuffers = x 
where x is the number of buffers to allocate, typically 2.

Additional query words: 2.20

Keywords :
Version : :2.2
Platform :
Issue type :


Last Reviewed: November 10, 1999