MS LAN Manager 2.1 Test Summary (Cemtech Ltd.)
ID: Q89112
|
The information in this article applies to:
-
Microsoft LAN Manager, version 2.1
SUMMARY
The following is a report of the test results of an OEM computer that
participated in the Microsoft Compatibility Lab's (MCL) test for
Microsoft LAN Manager version 2.1.
MORE INFORMATION
Address
Cemtech Ltd.
19 Fairmont Avenue
Ottawa, Ontario
Canada K1Y1X4
Phone Number
(613) 722-2222
(613) 722-6305 fax
HARDWARE CONFIGURATION
Manufacturer Cemtech Ltd.
Mode CEMServer 1 CEM-486C(33)IS
System serial number 780001
CPU/Speed/Bus type 80486DX/33/ISA
Installed RAM 16 MB
OS/OS version MS OS/2 1.3
BIOS/Rev./Date AMI 6/6/91
Motherboard assy. number 9149 910400507
Disk 1 Manufacturer/Model/Size Hewlett-Packard SCSI HP2235 428 MB
Disk Controller 1 Manufact./Model Adaptec AHA-1542B
Disk Controller 1 PCBA/Rev./BIOS 429307-00 C
Disk 2 Manufacturer/Model/Size Hewlett-Packard SCSI HP2235 428 MB
Disk Controller 2 Manufact./Model Adaptec AHA-1542B
Disk Controller 2 PCBA/Rev./BIOS 429307-00 C
Floppy drives One 3.5-inch 1.44 MB Panasonic
One 5.25-inch 1.2 MB Panasonic
Serial ports Two on Lava Complete MOKO LSO-1
(COM2 not wired)
Parallel ports One on Lava Complete MOKO LSO-1
Mouse manufacturer/model Logitech Dexxa
IRQ Assignments
2 2 2nd 8259A
3
4 COM1
5
6 Floppy
7 LPT1
8 Clock
9 Redirected IRQ2
10
11 SCSI 1
12 COM2
13 Math coprocessor
14
15 SCSI 2
I/O Ports
230 SCSI 1
330 SCSI 2
378 LPT1
3F8 COM1
2F8 COM2
DMAs
5 SCSI 1
7 SCSI 2
Network Interface Cards
Ethernet Token-Ring
3Com EtherLink/II TP WD 8015 TR
Novell NE1000 3Com TokenLink
Novell NE2000 IBM TR II
WD 8013 IBM TR 16/4 @ 4 MB
EtherFlex 16B IBM TR 16/4 @ 16 MB
QUALIFYING TEST RESULTS
Test Focus Pass Anomalies and/or Workarounds
---------- ---- ----------------------------
Disk Yes
Keyboard Yes
Monitor Yes
Mouse Yes No dedicated mouse port - used COM1
Net Yes
Print Yes
Serial Yes
Speaker Yes
Stress Yes
UPS Yes
Video Yes
FINAL TEST RESULTS
Test Focus Pass Anomalies and/or Workarounds
---------- ---- ----------------------------
MS-DOS 5.0 UMB load-high support Yes
Fault tolerance Yes
Install/setup/reconfiguration Yes
Named pipes Yes
Network functionality Yes
Network installation for clients Yes
OS/2 file systems Yes
Printing Yes
Remote Access Services support Yes
RIPL Yes
Stress Yes
Uninterruptible Power Supply Yes
Miscellaneous Anomalies and/or Workarounds
3Com EtherLink Plus NICs would not work with this hardware
configuration, with errors reported as either OS/2 traps or LAN
Manager bind errors.
Racal 6510 NICs also would not work in this hardware configuration,
with errors reported as either OS/2 traps or LAN Manager bind errors.
Additional query words:
2.10 Certification MCL RAS UPS
Keywords :
Version : :2.1
Platform :
Issue type :