Switch to NetBEUI or MasterLAN Card to Avoid Trap 0008

ID: Q98847


The information in this article applies to:
  • Microsoft LAN Manager, versions 2.0, 2.1, 2.1a, 2.2


SUMMARY

A Hewlett-Packard (HP) Vectra 486/66T with an HP Ethertwist/32 card, running the A0.00.06 drivers from HP with the UB XNS protocol (version 16.62 with and without UBLOOP) causes the server to Trap 0008 when receiving a large (100 MB+) data transfer. The same problem has been experienced with a 3Com Etherlink III.

To avoid this, switch to NetBEUI or an Ungermann-Bass (UB) MasterLAN card. (UB and HP are investigating this further.)

Additional query words: 2.00 2.0 2.10 2.1 2.10a 2.1a 2.20 2.2

Keywords :
Version : :2.0,2.1,2.1a,2.2
Platform :
Issue type :


Last Reviewed: November 10, 1999