The information in this article applies to:
BUG# ODBCSDK2: 2693 (2.0) SYMPTOMS
When connecting from a 16-bit application to a certain 32-bit driver in a
Microsoft Windows NT environment, you may receive an error from the driver
about incorrect parameter or argument value. This does not happen when
SQLConnect is called from a 32-bit application to a 32-bit driver or from a
16-bit application to a 16-bit driver.
In looking at the ODBC trace using 32-bit ODBC Spy, you will find that the
value of cbDSN passed is not 8, but a large number (0x3a43).
CAUSEWhen connecting from a 16-bit application to a 32-bit driver, the value of cbDSN in SQLConnect is not correctly passed and is mapped to a large value. However, the values of cbUID and cbAuthStr are passed correctly. STATUSMicrosoft has confirmed this to be a problem in ODBC Driver Manager version 2.0. We are researching this problem and will post new information here in the Microsoft Knowledge Base as it becomes available. Additional query words: ODBC MSVC DM invalid 14915
Keywords : |