XCLN: Setup/Attempt to Restart Fails on Windows NT

ID: Q142579


The information in this article applies to:
  • Microsoft Exchange Server, version 4.0
  • Microsoft Exchange Windows NT client, versions 4.0, 5.0


SYMPTOMS

When you run SETUP.EXE for Microsoft Exchange Electronic Forms Designer on a Windows NT computer, the following dialog box may appear when the Electronic Forms Designer Setup program tries to restart Windows NT:

Installation Microsoft

This Windows application cannot respond to the End Task request. It may be busy, waiting for a response from you or may have stopped executing.

Select Cancel to return to Windows NT.

Select End Task to close this application immediately. You will lose any unsaved information in this application.

Select Wait to give the application 5 seconds to finish what it is doing and then try to close the application again

[WAIT] [END TASK] [CANCEL]


CAUSE

This is fairly typical of some 16-bit application setups on Windows NT. The system merely has not given the setup routine enough time to shut down. Selecting the Wait button on the shut down dialog box will enable the setup routine to complete its shut down process.

Additional query words: winnt setup

Keywords : kbsetup kbbug4.00 XCLN
Version : 4.0 5.0
Platform : WINDOWS
Issue type :


Last Reviewed: March 11, 1999