XCON: MTA Event Id 248: Too Many ECBs Processed in One Thread

ID: Q152900


The information in this article applies to:
  • Microsoft Exchange Server, version 4.0


SYMPTOMS

The Microsoft Exchange Message Transfer Agent (MTA) reports repeated occurrences of Event ID 248.

MSExchangeMTA Event ID 248
Too many ECBs processed in one thread.
No. of ECBs processed: %1.


STATUS

Microsoft has confirmed this to be a problem in Microsoft Exchange Server version 4.0. This problem was corrected in Microsoft Exchange Server 4.0 U.S. Service Pack 2. For information on obtaining the service pack, query on the following word in the Microsoft Knowledge Base (without the spaces):

S E R V P A C K

Additional query words: connector mta

Keywords : kbusage kbbug4.00 kbfix4.00.sp2 XADM exc4
Version : winnt:4.0
Platform : winnt
Issue type : kbbug


Last Reviewed: June 14, 1999