The information in this article applies to:
SYMPTOMSThe Microsoft Exchange Message Transfer Agent (MTA) version 5.0 may terminate unexpectedly when performing distribution list (DL) expansion on a large, nested DL. An event similar to the following may be logged in the application event log:
MORE INFORMATION
This problem may occur if, for example, there are 26 DLs nested beneath a
single DL where the number of members to any one of the nested DLs may
range from 0 to 600 or more. When a message is sent to the DL that contains
the 26 nested DLs, the MTA may terminate unexpectedly with the 9405 event
ID.
The DISP:FANOUT indicates a problem expanding an object, in this case, a large distribution list that contains a number of other distribution lists. The presence of the 06000000 as the Object at Fault is another indication of this particular issue. STATUSMicrosoft has confirmed this to be a problem in Microsoft Exchange Server version 5.0. This problem was corrected in the latest Microsoft Exchange 5.0 Server U.S. Service Pack. For information on obtaining the service pack, query on the following word in the Microsoft Knowledge Base (without the spaces): S E R V P A C K Additional query words:
Keywords : kbusage kbbug5.00 XFOR kbfix5.00.sp1 |
Last Reviewed: March 29, 1999 © 2000 Microsoft Corporation. All rights reserved. Terms of Use. |