XCON: Dynamic RAS Connector Cannot Deliver Mail

ID: Q158279


The information in this article applies to:
  • Microsoft Exchange Server, version 4.0


SYMPTOMS

This problem occurs when using the Traditional Chinese version of Windows NT Server 3.51. If you use a message transfer agent (MTA) with a name different from the Microsoft Exchange Server name, when you send mail by a dynamic RAS connector, the modem will dial out but no mail message is transferred. Warning messages similar to the following appear in the application log:

Event ID 289
A connection to /O=MSFT/OU=RANDYYEH_CC1/CN=CONFIGURATION/CN=CONNECTIONS/CN=RAS_CON_80 could not be opened. [MTA XFER-IN 19 26] (12)
Event ID 1294
An association with entity /O=MSFT/OU=RANDYYEH_CC1/CN=CONFIGURATION/CN=CONNECTIONS/CN=RAS_CON_80 ended abnormally. [1 1 0 0 PLATFORM KERNEL 22 130] (10)
Event ID 9316
An RPC communications error occurred. No data was sent over the RPC connection. Locality table (LTAB) index: 7. Windows NT error: 9301. The MTA will attempt to recover the RPC connection. [BASE IL PIPE RAS 36 500] (12)
Event ID 9311
A RAS communications error has occurred for gateway /o=msft/ou=RANDYYEH_CC1/cn=Configuration/cn=Connections/cn=RAS_CON_80. RAS error code returned: 0, RAS Table index: 0. The MTA will attempt to recover the RAS connection. [BASE IL PIPE RAS 36 230] (12)


WORKAROUND

Use the same MTA name as the Microsoft Exchange Server name.

Additional query words: Tradchin

Keywords : kbusage XCON
Version : winnt:4.0
Platform : winnt
Issue type :


Last Reviewed: April 7, 1999