XCON: Only a Few Messages Delivered over X.400 Connector

ID: Q158589


The information in this article applies to:
  • Microsoft Exchange Server, version 4.0


SYMPTOMS

This problem occurs when you use the Chinese version of Windows NT 3.51. An X.400 connector over TP4 stack is used to connect to Microsoft Exchange Server in a different site, and the Use Expedited Data check box on the X.400 connector Stack property page is selected. The message transfer agent (MTA) only delivers one to four mail messages to the remote site and then stops. Restarting the MTA does not resolve the problem.


WORKAROUND

Clear the Use Expedited Data check box on Stack property page.

Additional query words:

Keywords : XCON
Version : winnt:4.0
Platform : winnt
Issue type :


Last Reviewed: April 7, 1999
© 2000 Microsoft Corporation. All rights reserved. Terms of Use.